Service Hotline 18617145297
test project
alternating damp heat test
reference standard
GB/T 2423.4-2008; IEC 60068-2-30: 2005
GB/T 2423.34-2012; IEC 60068-2-38: 2009
capabilities
Temperature range: -70℃~180℃;
Humidity range: 20%RH~98%RH;1m×1m×1m
Alternating damp heat test refers to the periodic high and low temperature moist heat cycle test of temperature and humidity. It can constitute an alternate process of water vapor condensation and drying to accelerate the corrosion process. It is a common climate environment test. Alternating damp heat test simulates the impact of changes in environmental temperature and humidity on the product, and accelerates the corrosion process by alternating changes between temperature and humidity to evaluate the reliability and durability of the product. The main purpose of the test is to determine the suitability of a component, equipment, or other product for transportation, storage, and use under conditions that combine high humidity and temperature cycling, and typically produce condensation on the surface of the test specimen.
Application fields of high and low temperature alternating damp heat test:
Road traffic: road vehicle electronic and electrical equipment, rail transit locomotive and vehicle equipment and devices, automobile parts, etc.
Computers: computers, displays, mainframes, computer components, medical equipment and other precision instruments
Electronic communications: mobile phones, radio frequency devices, electronic communication components, etc., PCB, PCBA.
Electrical appliances: home appliances, lamps, transformers and other home appliances and electrical equipment, instrumentation, medical equipment;
Others: Packaging boxes, transportation equipment, etc.
Reference standard for high and low temperature alternating damp heat test (high temperature):
GB/T 2423.2, IEC 60068-2-2, EIA-364-17, MIL-STD-810F, etc.
Reference standard for high-low-temperature alternating damp heat test (low temperature):
GB/T 2423.1, IEC 60068-2-1, EIA-364-59, MIL-STD-810F, etc.
Processing process for alternating damp heat test report
1. Customer consultation;
2. Evaluate the quotation;
3. The applicant signs a testing contract with our company;
4. Payment by the applicant;
5. The applicant shall provide samples and materials (signed and stamped quotation, completed application form and payment voucher);
6. Test the samples (if the test fails, make rectification);
7. Issue a report after completing the test.