Service Hotline 18617145297
1.background introduction
IP level protection testing is a basic project that electronic products often need to do. Many customers often get confused when choosing whether to make IP69 or IP69K for their products. This article combines GB4208 (IEC 60529), a representative standard for general consumer electronics products, and GB30038 (ISO 20653), a representative standard for automotive parts.
2. Specific test conditions for IP protection

The solid foreign matter prevention conditions for IP5X are as follows: 1. Place the sample in the dust box according to the normal working position and not connected to the vacuum pump; 2. Test dust: talc powder; 3. Test time: 8 hours. nbsp; The solid foreign body prevention conditions for IP6X are as follows: 1. Place the sample in a dust box according to the normal working position and connect it to the vacuum pump; 2. Test dust: talc powder; 3. Test time: pumping rate per hour is 40~60 times the shell volume, test time is 2 hours; hourly pumping rate <40 times the shell volume, test time is 8 hours vacuum pressure difference: ≤2kPa(20mbar)





The solid foreign matter prevention conditions for IP5 KX/IP6 KX are as follows:
1. Place the sample in the dust box according to the normal working position;
2. Test dust: Arizona powder;
3. Test time: Spray the air dust mixture for 6S and pause for 15 minutes. This is one cycle, a total of 20 cycles.
4. Judgment standard: IP5KX: A small amount of dust is allowed to enter, but it does not affect performance and safety;
IP6KX: No dust entering.



3. Summary-Differences and Differences between IP69 and IP 69K